Edition of the supplied seven-page2006 case study. Source prose and legible chart labels are retained, not independently validated or updated. Read original case study (PDF). Original PDF unchanged. Repeated bio-organic.com furniture is consolidated here. Source-page headings and identified diagram descriptions are editorial. This is a partial transcription: tiny gray chart text on source page 7 remains unreadable. Legible content is included; a clearer source is needed for complete equivalence.

Source page 1

CASE STUDY

Results Of Ecosystems Plus® Injection In Secondary Aeration

Lagoons Global Food Manufacturer (September 6-22 2006)

Primary Project Objectives::

Process flow diagram (editorial description)

GLOBAL FOOD MANUFACTURER–WWTP ESP INJECTION POINT. Food Manufacturing Discharge flows to an Influent Wet Well (.75 MGD), Flow Equalization Tanks With Mixers, then Anaerobic Bio-Reactors. A gas line connects the reactors to a Bio Gas Boiler and Gas Flare. Liquid flows to two Aeration Lagoons and then Clarifier1 and Clarifier2, before To Chlorine Contact and Discharge. DO Sample Points are #1 at the inlet, #2 near the lagoon beginning, #3 midway, #4 near the end, and #5-Discharge. RAS returns Activated Sludge to the lagoons; WAS goes to Sludge Storage, with Polymer Injection, then To sludge belt press and land application. Aeration Blowers connect to the lagoons. Clarifier Sample Point and Effluent24hr/Day Composite Sample Point are labeled. An EcoSystem Plus drum, Bio-Organic Catalyst Injection Point label and arrow point to the influent wet well in this schematic. This is distinct from the lagoon#3 injection location specified in the trial prose and next page; the original diagram is not altered. The source logo reads BIO-ORGANIC CATALYST, THE POWER IN NATURE®. Small product artwork reads NON-TOXIC AND SAFE and ENVIRONMENTALLY FRIENDLY.

Source page 2

ESP INJECTION POINT INTO LAGOON #3

Photograph of a churning brown-water lagoon. Arrows label the Aeration Building and Injection Point in the background; a Flow Direction arrow points toward the foreground/right.

SECONDARY AERATION LAGOON #3 WITH FINE BUBBLE DIFFUSERS AND SURFACE AERATORS

Photograph of aeration equipment and brown lagoon water. Labels identify Flow Equalization Tanks, Anaerobic Bio-Reactor Building, Secondary Clarifiers, and Flow Direction toward the right. Both photographs have a small right-pointing presentation-navigation icon.

Source page 3

Technology breakthrough greater aeration efficiency:

Technology breakthrough solubilization of lipids:

Study parameters (dissolved oxygen testing):

Secondary channel flows:

Secondary channel loading:

Study Start-up:

Study testing:

Results in secondary aeration lagoons (dissolved oxygen)

Results in secondary aeration lagoons (dissolved oxygen):

Source page 4

Comparison of total (DO) increases in secondary aerators:

Total DO chart (editorial description)

Legend distinguishes AVER Lagoon Loading Lbs of TCOD8/17-23/06 and9/6-22/06; Baseline DO Levels8/17-23/06; Combined With ESP Inj.9/6-22/06. The left axis Lbs of TCOD LOADING runs9000–16000 in1000 increments; the right DO mg/L axis runs0.2–1.2 in0.1 increments. Loading bars are labeled10,677 and14,818. Annotation: DO Increased45% Over Baseline, In spite of39% Increase in Lbs of TCOD. The full printed line labels follow.

Printed total DO chart values
LocationBaseline DO (mg/L)With ESP DO (mg/L)
Combined Lagoon 2&3 Header Box0.350.26
Combined Stage 10.490.69
Combined Stage 20.510.83
Combined Stage 30.890.71
Combined Discharge Box0.751.10

Comparison of (DO) increases with all surface aerators on:

All surface aerators on (editorial chart description)

Source legend: Baseline DO Levels 8/17-23/06; Aver 9/6-14 All Aerators On. Vertical axis DO mg/L, 0.2–1.4 in steps of0.2. Source annotation: DO Increased70% Over baseline. Values below are printed labels, not inferred bar heights.

Printed all-aerators-on DO values
LocationBaseline DO (mg/L)With ESP DO (mg/L)
Combined Lagoon 2&3 Header Box0.350.27
Combined Stage 10.490.77
Combined Stage 20.511.12
Combined Stage 30.891.01
Combined Discharge Box0.751.28

Source page 5

Comparison of (DO) increases with all surface aerators on:

Repeated all-aerators-on chart (editorial description)

Source legend: Baseline DO Levels 8/17-23/06; Aver 9/6-14 All Aerators On. Vertical axis DO mg/L, 0.2–1.4 in steps of0.2. Source annotation: DO Increased70% Over baseline. Values below are printed labels, not inferred bar heights.

Printed all-aerators-on DO values
LocationBaseline DO (mg/L)With ESP DO (mg/L)
Combined Lagoon 2&3 Header Box0.350.27
Combined Stage 10.490.77
Combined Stage 20.511.12
Combined Stage 30.891.01
Combined Discharge Box0.751.28

Secondary aeration Lagoons (NH3, TKN & TCOD Reductions):

Reductions of NH3 - N at clarifier:

NH3-N clarifier chart (editorial description)

Vertical axis NH3-N mg/L,0–9 in steps of0.5; daily categories9/6/06 through9/30/06 with ESP AVER INJ. PERIOD between9/22 and9/23. Printed baseline bar:6.35; ESP average injection-period bar:1.95. Annotations: ESP Inj Starts9/6 @3:30pm; ESP Inj Ends9/22; NH3-N AVER With ESP Inj. Reduced69.3%. A dashed baseline crosses the plot near6.35. The daily bars rise above baseline on9/7, then remain below baseline through the rest of the plotted dates. Unlabeled individual bar heights are not assigned invented values.

Source page 6

Reductions in TCOD at clarifier:

TCOD clarifier chart (editorial description)

Vertical axis TCOD mg/L,0–80 in steps of10; daily categories09/06/06 through09/29/06 with ESP AVER INJ. PERIOD between09/22 and09/23. Printed baseline bar58; printed ESP injection-period average37. Annotations: ESP Inj. Starts9/6; ESP Inj. Ends9/22; Aver TCOD Reduction Of36.2% With ESP INJECTION. The daily bars vary, with a high bar near70 on09/11; the remaining daily bars are below the baseline. Unlabeled bar heights are not transcribed as exact values.

Secondary aeration lagoons (TKN, NH3-N & nitrates) reductions in final discharge levels:

Improved final effluent discharges:

Final effluent chart (editorial description)

Vertical axis mg/L,0–5.5 in0.5 increments. Legend:24hr.comp.TKN mg/l; Ammonia as N mg/l; nitrate as N mg/l. Annotations: REDUCTION WITH ESP INJECTION68.6% in TKN,85.7% in Ammonia as N,83.3% in Nitrate as N; Continued “Carry Over Effect” Of ESP at10/4. Values below are the labels printed in this chart, including the source average category as shown.

Printed final effluent values
CategoryTKN mg/lAmmonia as N mg/lNitrate as N mg/l
60 day Baseline Aver5.11.40.3
9/64.81.800.26
9/133.80.400.53
9/201.60.100.05
Aver-With ESP Inj.3.40.80.3
10/41.50.100.39

Source page 7

Improvements in PO4-P discharges:

Improved removal of PO4-P discharges (influent vs effluent):

PO4-P removal chart (editorial description)

Vertical axis % Removal of Influent vs. Effluent Discharge PO4-P,88.0–98.0 in1.0 increments. A dashed line marks the89.6 baseline. Annotations: .3% Increase in % removal rate, In spite of a14% increase of Influent Loading;8% Increase In Removal Rate with ESP “Carry Over Effect”. Printed values follow. Tiny gray text inside the baseline and average outlined bars is not legible at the supplied image resolution and has not been guessed; the original PDF retains it.

Printed PO4-P removal chart values
CategoryRemoval (%)
60 day-Baseline Aver89.6
9/6/200689.3
9/13/200697.2
9/20/200689.9
9/27/200697.5
Aver With ESP Inj93.4
10/4/200697.4

Reductions in sludge volumes: