Full accessible transcription of the supplied seven-page Bio-Organic Catalyst case study reporting 2007 treatment observations. Claims, percentages, historical dosing recommendations and terminology below belong to the source; this edition does not independently validate them or provide new product-use advice. Original inconsistent figures and incomplete expressions are retained rather than reconciled. Added photograph and chart descriptions are labeled.

Read the original PDF. The original is unchanged.

Source branding: BIO-ORGANIC CATALYST · THE POWER IN NATURE® · CASE STUDY · bio-organic.com

Source page 1

Elimination Of Odors And Process Improvements In A Creamery Plant, Texas, USA With Eco-CatTM Injection Into SBR’s WWTP

Creamery Plant, Texas, USA Plant Description and Operational Issues

The creamery plant, produces butter products, including gourmet butter and unsalted butter. The waste water from the creamery flows into the WWTP, which consist of (two) 1 million gallon (3785m3) SBR’s. The SBR’s effluent flows either into (two) 2.9 million gallon aerated lagoons, (10,978 m3/lagoon) or is discharged into the local public WWTP.

Normally, effluent flows into the lagoons, where it is pumped as irrigation onto local farm lands. The WWTP has been receiving community odor complaints. The plant is normally operated at or below design flow capacity, but coincidently over influent COD design load consistently. This additional influent COD loading have caused the SBR’s to run very low DO levels (.16-.25mg/L). The SBR’s effluent flow into the lagoons have been suffering from low percentage removal of COD or TSS, which in turn has created low DO levels in the aeration lagoons.

Primary Project Objectives: Eco-CatTM Injection Into SBR’s

Monitor Eco-CatTM ability to increase the transfer of dissolved oxygen into the North and South SBR’s and it’s “carry over effect” into the aeration lagoons. Observe the improvements in percentage removal of COD and TSS in SBR’s and total plant removal (plant influent vs. irrigation effluent discharge). Monitor improvement in Lagoon Irrigation Effluent levels of COD, TSS, SS and DO-mg/LA baseline of measurements was established for the period 8/1/07 thru 8/20/07.

Eco-CatTM treatment was begun on 8/21/07. Results from 8/21 thru 9/05/2007 were compared against the baseline period.

bio-organic.com

Source page 2

Comparison of Influent COD Loading:

Program Of EcoCatalyst® Injection Into SBR’s

North SBR:

On 8/21/2007 20 gallons of EcoCatalyst® was added to a volume of 575,000 gallons or 2,177 m3. The COD- mg/l loading was 12,560. An additional 2.5 gpd (9.46 LPD) was added to maintain the constant level of Eco-CatTM based on average flow of .108 MGD (410 m3) with an average COD loading of 11,440 mg/L.

South SBR:

On 8/24 20 gallons of Eco-CatTM was added to a volume of 575,000 gallons or 2,176.62 m3. The COD Loading mg/l was 13,720. An additional 2.5 gpd (9.46 Liters) were added to maintain the constant level of Eco-CatTM based on average flow of .108 MGD (m3) with an average COD loading of 11,440 mg/L. The purpose of adding extra EcoCatalyst was to allow for the volume/loading retained in the decant cycle level in each SBR to produce rapid reaction of increased DO levels along with the breakdown of FOG’s.

Creamery Plant, Texas, USA– Aerial View of SBR’s and Aeration Lagoons

Aerial photograph: SBR’s and Aeration Lagoons

Image description: An aerial view identifies the Creamery Plant at lower left, two adjacent SBR’s above it, and two larger Aeration Lagoons immediately to the right of the SBR’s. Arrows connect these three printed labels to the structures.

bio-organic.com

Source page 3

2-SBR WWTP’s, 2-Aeration Lagoons

North and South SBR WWTP’s Two Aeration Lagoons

BOC’s Effect On Increasing Dissolved Oxygen- mg/L Levels in North and South SBR’s

Source photographs

North and South SBR WWTP’s: an open concrete treatment basin with orange-brown liquid, several surface aerators and perimeter rails. Two Aeration Lagoons: adjacent lined outdoor ponds divided by an embankment, with equipment along the near bank and visible surface agitation.

Source chart description: dissolved oxygen in the two SBR’s

Grouped bars: blue South SBR DO mg/L and red North SBR DO mg/L. Vertical axis DO-mg/L, printed ticks 0.00 to 5.00 in 0.20 increments. Horizontal labels: Baseline-8/1-8/20/2007 Aver; 8/21/2007, 8/22/2007, 8/23/2007, 8/24/2007, 8/25/2007, 8/26/2007, 8/27/2007, 8/28/2007, 8/29/2007, 8/30/2007, 8/31/2007, 9/1/2007, 9/2/2007, 9/3/2007, 9/4/2007, 9/5/2007; BOC AVE-8/21-9/5/07.

Callouts read “North SBR-BOC Addition begins 8/21” and “South SBR-BOC Addition begins 8/24”. Bars start near the bottom of the scale; the North SBR rises sharply on 8/22 and fluctuates thereafter. The South SBR rises later and peaks on 9/1. Daily values vary, and several South SBR bars exceed the corresponding North SBR bars. Final labeled averages are South 1.63 and North 2.43 mg/L. These are the only bar-value labels; daily bar heights are not transcribed as exact measurements.

bio-organic.com

Source page 4

The Benefits of Bio-Organic Catalyst Technology

BOC Technology Breakthrough With Solubilization Of Lipids:

Solubilization of fats, oils, and greases (FOGs). This is an accelerated natural catalytic process in which lipid ester bonds are rapidly cleaved, reducing their molecular structure to both glycerol and fatty acids.

Glycerol and fatty acids are then readily available to wastewater micro-organisms as a high-energy food source of carbon for enhancement of nitrification and de-nitrification reduction processes.

bio-organic.com

Source page 5

Results Of EcoCatalyst® Injection- 8/21 Thru 9/5/07 Vs. Baseline Of 8/1 Thru 8/20/07 In SBR’s

Influent Flows:

Influent COD:

North SBR

DO (Dissolved Oxygen) Levels Increased Rapidly:

COD Removal Rate:

TSS-Removal Rate:

South SBR

DO: 906% Increase over baseline. (.18 mg/L to 1.63 mg/L).

Removal Rate:

COD Average Decant Lbs/Day:

TSS - Removal Rate:

TSS - Average Decant Lbs/Day:

Overall Plant Removal Rates of COD And TSS (Plant Influent vs. Irrigation Effluent):

bio-organic.com

Source page 6

The “Carry Over Effect” From SBR’s into the Aerated Lagoons:

Irrigation Effluent - Increase In DO and Reduction Of SS mg/L

Source chart description: Irrigation Effluent-Increase In DO and Reduction Of SS mg/L

Maroon bars represent Irrigation Effluent DO mg/L, blue diamond-marked line represents SS mg/L. Left DO mg/L axis: zero shown as a dash, then 1.00 through 7.00 in 1.00 increments. Right SS mg/L axis: (50), zero shown as a dash, then 50 through 400 in 50 increments. Horizontal labels: Baseline-8/1-8/20/2007 Aver; 8/21/2007, 8/22/2007, 8/23/2007, 8/24/2007, 8/25/2007, 8/26/2007, 8/27/2007, 8/28/2007, 8/29/2007, 8/30/2007, 8/31/2007, 9/1/2007, 9/2/2007, 9/3/2007, 9/4/2007, 9/5/2007; BOC AVE-8/21-9/5/07.

Printed endpoint labels: DO 1.06 at baseline and 5.28 at BOC average; SS 379 at baseline and 98 at BOC average. A red dotted diagonal rises between the DO endpoints; a blue dashed diagonal falls between the SS endpoints. The daily bars generally rise, with an early dip on 8/26; the SS line generally falls with a prominent upward spike on 9/1, then a low on 9/2. Some dates lack plotted SS markers. No exact unlabeled daily values are inferred from the plot.

Observations By WWTP Staff (One Week After EcoCatalyst® Injection Begin - Week ending 8/26)

bio-organic.com

Source page 7

Summary Of Results With EcoCatalyst® Injection

Dissolved Oxygen Increases:

In spite of COD overloading issues, the North SBR DO mg/L improved by 1215% (baseline average .20 to 2.43 mg/L, with a peak of 4.31 with BOC treatment. The South SBR DO mg/L improved by 906% (baseline average .18 to 1.63 mg/L, with a peak of 4.67 with BOC treatment.

SBR Removal Rates Performance Improved:

Lagoons DO and Removal Rates Improved:

BOC Recommendations

Inject EcoCatalyst via pump into the each SBR (2.5 gpd into each SBR), rather than manual addition by hand. This will insure a more constant DO levels. The product is dose responsive and injection amounts can be varied accord to influent loadings.

bio-organic.com